IBM Tivoli Netcool/OMNIbus Version 8.1

Monitoring ObjectServer connections

You can view all current connections to the ObjectServer and disconnect one or more of the connections. You must be assigned the ALTER SYSTEM DROP CONNECTION permission to disconnect ObjectServer connections.

About this task

To view and disconnect connections to the ObjectServer:

Procedure

  1. From the Netcool/OMNIbus Administrator window, select the System menu button.
  2. Click Connections. The ObjectServer Connections pane opens, showing a row of information for each application that is currently connected.
  3. Select the rows that you want to disconnect. You can use the Shift key for consecutive selections, or the Ctrl key for non-consecutive selections.
  4. Click Disconnect in the toolbar. You are prompted in turn for confirmation that you want to disconnect each of the applications that you selected.
  5. Click Yes for each application to be disconnected, and click No to cancel a disconnection.